Abstract

AbstractThe redox mediator Meldola blue (MB) was entrapped into two polymers, poly‐1,2‐diaminobenzene (p‐DAB) and poly‐3,4‐ethylenedioxythiophene (p‐EDOT) by potential cycling and films were applied to NADH oxidation with subsequent glutamate detection using immobilized glutamate dehydrogenase. Both polymer films were tested for electrocatalysis of NADH using amperometry at Eapp=0.1 V vs. Ag/AgCl and similar response characteristics were obtained with sensitivity values of 6.1 nA μM−1, linear range up to 0.5 mM (R2=0.9972) and LOD of 50 μM. Subsequent amperometric determination of glutamate resulted in sensitivity 0.7 nA μM−1, linearity 0–100 μM and detection limit of 2 μM glutamate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.