Abstract

Glassy carbon electrode modified with electrodeposited nickel oxide nanoparticles (NiOxNPs) was used as electrocatalyst for oxidation of omeprazole and pentoperazole in alkaline solution. The modified electrode exhibited efficient electrocatalytic activity for the oxidation of omeprazole and pentoperazole with relatively high sensitivity, excellent stability, and long lifetime. Hydrodynamic amperometric method is used for determination of selected analytes. Under optimized condition, the linear concentration range, detection limit, and sensitivity of modified electrode toward omeprazole detection are 4.5–120 μM, 0.4 μM (at signal to noise 3), and 40.1 nA μM−1 cm−2, respectively. For pantoperazole, hydrodynamic amperometric determination yielded calibration curve with linear range of 2.5–180 μM, detection limit of 0.2 μM, and sensitivity of 39.2 nA μM−1 cm−2, respectively. The proposed method was successfully applied to pentoperazole and omeprazole determination in drug samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.