Electrochemical machining (ECM) is promising to machine the complex surface due to the advantages of no tool wear, stress free, and good machining accuracy. In this study, a machining method of the spiral internal ribs by ECM is presented. Firstly, the ECM experimental system is developed, which consists of electrolyte supply module, power supply unit, and workpiece-holding device. Then, a shaped cathode was used to process the spiral-turbulated hole on the built system. The shaped cathode was prepared by means of ultraviolet-curing mask method considering the expected spiral turbulator’s shape. Furthermore, parameters affecting the machining accuracy in shape duplication and machining efficiency are analyzed and discussed, especially the voltage and electrolyte concentration which have the main effect on the processed results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The International Journal of Advanced Manufacturing Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.