Abstract

Thefirst dual immunosensoris reportedfor the determination of IL-12 and IL-23, two relevant biomarkers of Crohn's disease (CD). The strategy relies on the selective capture of the targets by the respective antibodies which were covalently immobilized onto SPCEs modified with crystalline nanocellulose (CNC) and multi-walled carbon nanotubes (MWCNTs) followed by conjugation with a detector antibody labelled with poly-HRP-Strept and amperometric transduction using the H2O2/HQ system. The combination of CNC, a nanomaterial scarcely exploited in immunosensing, with MWCNTs enables the preparation of a novel dual immunosensor for the determination of CD biomarkers in clinical samples, including faeces. The developed bioplatform exhibits a high reproducibility and selectivity allowing the simultaneous determination of IL-12 and IL-23 using a smaller sample volume and in a much shorter assay time than those reported for each target with commercial ELISA kits. The dual immunosensor was successfully applied to the analysis of raw serum and faeces spiked with IL-12 and IL-23 at the expected levels in patients with severe CD.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.