Abstract

The corrosion behavior along with biocompatibility and mechanical properties plays an important role in determining of biomedical implants feasibility. Diamond-like carbon seems to be the promising material in which all these three requirements can be achieved. In this study nitrogen doped amorphous carbon (a-C:N) films were deposited on silicon and medical CoCrMo alloy substrates by vacuum glow discharge sputtering technique using different deposition conditions from graphite target. Potentiodynamic polarization tests were employed to assess the corrosion performances of the films at room temperature in 0.89 wt. % NaCl solution. The influence of substrate bias on the electrochemical corrosion behavior was investigated. The highest value off Ecorr for CoCrMo substrate was measured on the coating deposited with substrate bias around −0.6 kV. The shift of Ecorr to more positive values was about 350 mV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.