Abstract

Electrochemical behavior of a carbon paste electrode (CPE) modified with nickel(II)-5, 11, 17, 23-tetra-tert-butyl-25, 27-bis(diethylcarbamoylmethoxy) calix[4]arene (Ni (II)-L) complex and its electrocatalytic activity towards the oxidation of hydrogen peroxide were investigated by cyclic voltammetric technique in a 5.0×10−2 mol/L NaClO4+1.0×10−3 mol/L NaOH solution. It was found that Ni(II)-L acts as an effective catalyst for the oxidation of hydrogen peroxide. The modified electrode exhibited a linear response over a hydrogen peroxide concentrations in the range of 2.0×10−5−1.0×10−4 mol/L with a detection limit as low as 1.0×10−6 mol/L. The relative standard deviation was 3.5% for 5 successive determinations of H2O2 at 1.0×10−5 mol/L. The modified electrode was used successfully in rainwater analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.