Abstract

ObjectivesThe aim of this study is to describe electrocardiographic changes and conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI). Methods76 patients who underwent TAVI using Edwards Sapien 3 prosthesis were included, comparing electrocardiographic registries at admission, post-procedure and before discharge. ResultsPatients after TAVI presented a longer PR interval, a wider QRS, and a longer corrected QT, with a left deviation of QRS axis and T waves; reversible changes that tended to correct in the following days after TAVI. Complete atrioventricular block incidence was 2.9%. New-onset left bundle branch block (LBBB) incidence was 39%, although solved in almost half of patients before discharge. ConclusionsTAVI was associated with different reversible electrocardiographic changes that suggest a transient impact on the conduction system. One of every five patients presented permanent LBBB after valve implant.