Abstract

The aim of this study is to describe electrocardiographic changes and conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI).76 patients who underwent TAVI using Edwards Sapien 3 prosthesis were included, comparing electrocardiographic registries at admission, post-procedure and before discharge.Patients after TAVI presented a longer PR interval, a wider QRS, and a longer corrected QT, with a left deviation of QRS axis and T waves; reversible changes that tended to correct in the following days after TAVI. Complete atrioventricular block incidence was 2.9%. New-onset left bundle branch block (LBBB) incidence was 39%, although solved in almost half of patients before discharge.TAVI was associated with different reversible electrocardiographic changes that suggest a transient impact on the conduction system. One of every five patients presented permanent LBBB after valve implant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.