Abstract

AbstractThe electrical reliability of Ta/NiMn/NiFe/Co/Cu/Co/NiFe/Ta top spin valve sensors was studied. Electrical current densities in the range of 20–50 MA/cm2 were applied at 70°C ambient temperature. The combined Joule and ambient heating correspond to peak sensor temperatures of 170–300°C. Resistance and giant magneto-resistive (GMR) amplitude of the sensors were measured with time up to 800 hours. Device reliability was predicted from the Arrhenius plots of time to failure (TTF). Microstructure of sensors after stress was studied by scanning transmission electron microscope (STEM) and energy dispersive X-ray spectroscopy (EDX). The device failure mechanism is discussed on the scope of inter-layer diffusion and electromigration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.