Abstract

IntroductionElectrical muscle stimulation (EMS) is an FDA-approved thromboprophylactic method. Thrombus pathogenesis is considered to depend on factors related to components of the vessel wall, the velocity of blood, and blood consistency—collectively known as, the Virchow’s triad.ObjectiveThe testimony supporting the thromboprophylactic effects of the EMS is reviewed. An emphasis is placed on the fact that, EMS has demonstrated, in certain circumstances, an efficacy rate that cannot be fully explained by the Virchow’s triad; also that, in reviewing relevant evidence and the theorized pathophysiological mechanisms, several findings collectively point to a potentially missed point. Remarkably, venous thromboembolic disease (VTE) is extremely more common in the lower versus the upper extremities even when the blood velocities equalize; EMS had synergistic effects with intermittent compressive devices, despite their presumed identical mechanism of action; sleep is not thrombogenic; non-peroperative EMS is meaningful only if applied ≥5 times daily; neural insult increases VTEs more than the degree expected by the hypomobility-related blood stasis; etc. These phenomena infer the presence of a 4th thrombogenetic factor: neural supply to the veins provides direct antithrombic effects, by inducing periodic vessel diameter changes and/or by neuro-humoral, chemically acting factors. EMS may stimulate or substitute the 4th factor. This evidence-based hypothesis is analyzed.ConclusionA novel pathophysiologic mechanism of thrombogenesis is supported; and, based on this, the role of EMS in thromboprophylaxis is expanded. Exploration of this mechanism may provide new targets for intervention.

Highlights

  • Electrical muscle stimulation (EMS) is an FDA-approved thromboprophylactic method

  • According to Virchow’s classical triad (Virchow 1856), thrombus pathogenesis depends on factors related to components of the vessel wall; of the velocity of blood flow; and of the blood consistency

  • Electrical muscle stimulation (EMS), the application of electrical current usually through superficial electrodes placed over the main muscle groups of the lower extremities, inducing repeated muscle contractions, is an FDA-approved method for postoperative venous thromboembolic disease (VTE) prophylaxis

Read more

Summary

Objective

The testimony supporting the thromboprophylactic effects of the EMS is reviewed. An emphasis is placed on the fact that, EMS has demonstrated, in certain circumstances, an efficacy rate that cannot be fully explained by the Virchow’s triad; that, in reviewing relevant evidence and the theorized pathophysiological mechanisms, several findings collectively point to a potentially missed point. Venous thromboembolic disease (VTE) is extremely more common in the lower versus the upper extremities even when the blood velocities equalize; EMS had synergistic effects with intermittent compressive devices, despite their presumed identical mechanism of action; sleep is not thrombogenic; non-peroperative EMS is meaningful only if applied ≥5 times daily; neural insult increases VTEs more than the degree expected by the hypomobility-related blood stasis; etc. These phenomena infer the presence of a 4th thrombogenetic factor: neural supply to the veins provides direct antithrombic effects, by inducing periodic vessel diameter changes and/or by neuro-humoral, chemically acting factors.

Conclusion
Findings
Discussion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.