TiW barrier properties have been investigated by electrical testing of shallow CoSi2 junctions. Rutherford backscattering and Auger analyses have been used to study Al(0.5% Cu)/TiW/CoSi2/Si structure. Based on the electrical data, it was demonstrated that 900 Å of TiW will serve as a good diffusion barrier up to 475 °C/30 min. The junctions failed at 450 °C when TiW thickness was reduced to 450 Å. The electrical data show the stress of TiW film does not show any significant effects on its properties. Furthermore, shallower junctions (i.e., p+n ) are more vulnerable to barrier failure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.