Abstract

To identify the electrical characteristics of dielectric breakdown of growing oxide film during plasma electrolytic oxidation (PEO) process, a real-time identification method based on pulse test technique was presented. The voltage–current characteristic curve and impedance curve of pulse tests were analyzed. A sharp increase in pulse current was observed when applied potential increased to critical breakdown voltage, and the breakdown voltage and absolute impedance value of oxide film increased with processing progress. Therefore, the electrical characteristics identification technique could be used for process diagnostics and self-adaptive control of PEO process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.