Abstract

Results are presented from a study of electrical breakdown of anodic aluminum oxide in a constant field with a platinum pressure electrode. Statistical breakdown parameters and their dependence on the magnitude and polarity of the applied voltage are obtained. Field and temperature dependences of breakdown delay time τ over the interval 10−6–103 sec are determined. It is shown that the experimental τ(E) curves can be rectified (in two segments) in the coordinates log τ ∼ E−1. This indicates a possible contribution to the breakdown mechanism by both tunnel injection of electrons from the cathode and subsequent avalanche multiplication of electrons within the dielectric.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.