Abstract

The study aimed to investigate diaphragm respiratory drive modulation through electrical activity of the diaphragm (EADi) during progressive cycling in endurance-trained men (N=7) and to test day-to-day measurement reliability. Normalized EADi increased at exercise intensities from 40% workload (WL) to 70% and 85%WL but plateaued from 70% to 85% (p<0.05). V˙O2, V˙CO2, V˙E, increased at all exercise intensities, where Vt and BF increased from 40% to 55% WL and from 70% to 85% and RER increased at 70% and 85% (p<0.05). Bland–Altman plots of normalized EADi showed bias of 0.9% and −6.4% and limits of agreement of ±36.0% and ±30.4% for absolute measurements and relative changes from 40% WL, respectively. Within-day variability appeared constant indicating that measurements within a trial are reliable. Results suggest that diaphragm respiratory drive increases at moderate exercise intensities, but plateaus at high intensities where other respiratory muscles might contribute significantly to the breathing effort, perhaps to “protect” against diaphragm fatigue.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.