Abstract
Renewable energy penetration increases Smart Grid (SG) instability. A power balance between consumption and production can mitigate this instability. For this, intelligent and optimizing techniques can be used to properly combine and manage storage devices like Electric Vehicle Batteries (EVBs) with Demand-Side Management (DSM) strategies. The EVB helps distribution networks with auxiliary services, backup power, reliability, demand response, peak shaving, lower renewable power production’s climate unpredictability, etc. In this paper, a new energy management system based on Artificial Neural Networks (ANNs) is developed to maximize the performance of islanded SG-connected EVBs. The proposed ANN controller can operate at specified periods based on the demand curve and EVB charge level to implement a peak load shaving (PLS) DSM strategy. The intelligent controller’s inputs include the time of day and the EVB’s State of Charge (SOC). After the controller detects a peak demand, it alerts the EVB to start delivering power. This decrease in peak demand enhances the load factor and benefits both SG investors and end users. In this study, the adopted SG includes five parallel Distribution Generators (DGs) powered by renewable resources, which are three solar Photovoltaics (PVs) and two Wind Turbines (WTs). Sharing power among these DGs ensures the SG’s stability and efficiency. To fulfill demand problem-free, this study dynamically alters the power flow toward equity in power sharing using virtual impedance-based adaptive primary control level. This study proposes a decentralized robust hierarchical secondary control system employing Genetic Algorithm (GA)-optimized Proportional-Integral (PI) controller parameters with fine-grained online tuning using ANNs to restore frequency and voltage deviations. The proposed system is evidenced to be effective through MATLAB simulations and real-time data analysis on the ThingSpeak platform using internet energy technology. Our presented model not only benefits users by enhancing their utility but also reduces energy costs with robust implementation of a control structure by restoring any frequency and voltage deviations by distributing power equally among DGs regardless of demand condition variations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.