Abstract

Electro-chemical Chloride Extraction (ECE) is considered one of the most effective technique used to extract chloride ions from reinforced concrete structures. Effectiveness of using ECE depends on some important factors such as anode type, current intensity, extraction duration, type of rebar and chemical properties of concrete. On the other hand, ECE may cause some detrimental effects on some mechanical properties of concrete and steel such as a reduction in bond and compressive strengths of concrete, and embrittlement (i.e. reduction in ductility) ductility of reinforcing steel. The major aim of this research work was to investigate the effectiveness of ECE using locally available un-galvanized steel mesh with conductive cement paste anode as a new type of anode on a reinforced concrete slab as a structural element. The slab behavior before and after ECE was studied by determining compressive strength, water absorption rate, concrete chloride content and steel corrosion potential. The slab behavior was studied taken into consideration the established steel arrangement with spacing 20 cm between re-bars. Another aim of this research work was to investigate the effect of initial chloride content on chloride extraction efficiency by applying optimum current intensity and duration (3 A/m2 and 6 weeks) on cylinders with pure chloride content 0.4% and 0.8% (by weight of cement). Effectiveness of ECE with small initial chloride content 0.4% and 0.8% was compared with that of high initial chloride content (2.5%) in order to know if the initial chloride content is an important factor on ECE effectiveness or not.

Highlights

  • Corrosion is one of the most serious problems which has a bad effect on reinforced concrete properties [1], [2]

  • Electro-chemical Chloride Extraction (ECE) treatment was applied to a reinforced concrete slab as a structural element to know the effectiveness of the ECE on the reinforced concrete element

  • The reinforced steel bar arrangement effect on chloride extraction was studied by drilling powder from different locations of the slab, corrosion potential of steel re-bars, water absorption rate of concrete and compressive strength of concrete before and after ECE were studied

Read more

Summary

Introduction

Corrosion is one of the most serious problems which has a bad effect on reinforced concrete properties [1], [2]. Carbonation is considered one of the main important causes of corrosion which causes neutralization of all alkaline ingredients in cement due to a remarkable drop in PH value [3]. This drop will cause extensive widespread corrosion of reinforcing steel. Mohamed Abdel Moaty Khalaf, Structural Engineering department, Ain Shams University, Cairo, Egypt.

Methods
Results
Conclusion