Abstract

The necessary intensity of burning and completeness of fuel burning out in furnace volume are reached by the correct supply organization and the subsequent mixture of fuel with secondary air that is provided with burner devices. Experimental research of fuel oil and gas combustion efficiency in boiler furnaces of thermal power plant has shown that, the peripheral axial twist executed in the form of two channels with axial scapular air rotator is preferable. The combined gas supply is perspective: tubular peripheral and pilot central. For fuel oil combustion at large expenses the most effective burning is reached due to application of steam-mechanical nozzles which main lack is the considerable length of a torch. The two-tiered arrangement of burners in boiler at combustion of gas and fuel oil is more effective, in comparison with single-tier, both at the counter direction, and at unilateral frontal. For increasing the efficiency of combustion of fuel at some burners types in a boiler furnace the ascending vertical rotation of a torch can be created by the asymmetrical counter arrangement of burners of the first and second tiers. Use of the smoke exhauster of gases recirculation for reduction of harmful emissions of nitrogen oxides with boilers flue gases gives bigger effect in comparison with optimization of the choice of a layout arrangement of burners and parameter of a twist.