Abstract

Background ContextThe efficacy and safety of recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute in spinal fusion has been widely researched. However, no study of the efficacy and safety of Escherichia coli-derived rhBMP-2 (E.BMP-2) with a hydroxyapatite (HA) carrier has been proposed. PurposeThis study aimed to compare the efficacy and safety of fusion materials between E.BMP-2 and autogenous iliac bone graft in posterolateral fusion (PLF). Study Design/SettingAn open, active-controlled, randomized, multicenter trial was carried out. Patient SampleThis study included 93 patients who underwent single-level lumbar or lumbosacral PLF. Outcome MeasuresThe primary outcome measure was computed tomography (CT)-based fusion rate at 12 and 24 weeks. Secondary outcome measures were fusion grade by radiographs and CT at 12 and 24 weeks and changes in Oswestry Disability Index (ODI), Short Form-36 (SF-36) Health Survey, and visual analogue scale (VAS). MethodsPatients who underwent 1-level PLF (between L1 and S1) for severe spinal stenosis or grade 1 spondylolisthesis were randomized to receive E.BMP-2 with an HA carrier (E.BMP-2 group) or autogenous iliac bone graft (AIBG group). Thin-section CT (<2 mm), VAS, ODI, and SF-36 were obtained pre- and postoperatively at 12 and 24 weeks. Outcome measures were compared between the groups. ResultsA total of 100 patients were enrolled in this trial. Among them, 93 patients underwent planned surgery. Preoperative demographic and clinical data showed no difference between groups. CT-based fusion rates were 100.0% (41/41) for the E.BMP-2 group and 90.2% (46/51) for the AIBG group (p=.062) at 12 weeks and 100.0% (41/41) and 94.1% (48/51) (p=.251) at 24 weeks, respectively. Fusion grade based on radiographs and CT showed non-inferiority of the E.BMP-2 group compared with the AIBG group. All clinical parameters improved postoperatively. However, there was no difference in changes in VAS, ODI, or SF-36 between the groups. No serious adverse event related to E.BMP-2 was found. ConclusionsThe fusion rate of E.BMP-2 was comparable with that of AIBG following PLF. Good clinical efficacy and safety of E.BMP-2 in spinal fusion were also revealed. It was also suggested that HA shows suitability as a carrier for E.BMP-2. Thus, E.BMP-2 with an HA carrier can be an alternative bone graft material in spinal fusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.