Abstract
To evaluate the safety and efficacy of transcatheter arterial embolization (TAE) in controlling hemodynamically unstable bleeding following a percutaneous transthoracic needle biopsy (PTNB). A total of seven patients (four men and three women; mean age, 62 ± 12 years) who received TAE for post-PTNB bleeding between May 2007 and March 2022 were included. The observed types of bleeding were hemothorax (n = 3), hemoptysis (n = 2), and a combination of both (n = 2). In patients with active bleeding, the technical success of TAE was defined as superselective embolization of the target artery with no active bleeding visible on post-TAE angiography. Clinical success was defined as sustained cessation of bleeding without hemodynamic instability, requirement of repeat TAE, or the need for post-TAE hemostatic surgery during the initial admission. The metrics analyzed included technical and clinical success rates, complications, and 30-day mortality. All seven patients achieved technical success, with a clinical success rate of 86% (6/7). Six patients were discharged alive, while one patient died of respiratory failure accompanied by hemothorax 19 days post-biopsy. The angiographic findings associated with bleeding were contrast media extravasation or pseudoaneurysm (n = 3) and vascular hypertrophy with tortuosity (n = 2). The implicated bleeding arteries included the intercostal artery (n = 2), bronchial artery (n = 2), and internal thoracic artery (n = 1). In two cases, no clear bleeding foci were identified; nonetheless, prophylactic embolization was performed on the right intercostal artery (n = 1) and right intercostobronchial trunk (n = 1). The embolic agents utilized included microcoils (n = 1), gelatin sponge particles (n = 2), polyvinyl alcohol (PVA) with gelatin sponge particles (n = 1), PVA with microcoils (n = 1), microcoils with gelatin sponge particles (n = 1), and microcoils with n-butyl-2-cyanoacrylate and gelatin sponge particles (n = 1). The 30-day mortality rate was 14% (1/7). No ischemic complications related to TAE were observed. The study suggests that TAE is safe and effective for controlling hemodynamically unstable bleeding following a PTNB.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Diagnostic and interventional radiology (Ankara, Turkey)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.