Abstract

This study evaluated efficacy and safety of implanting two second-generation trabecular micro-bypass stents (iStent inject/iStent inject W) with phacoemulsification, either with or without iAccess Precision Blade goniotomy, in patients with mild-to-moderate open-angle glaucoma (OAG). This retrospective, non-randomized, unmasked, dual-arm, single-site, multi-surgeon, consecutive case series evaluated all OAG eyes that underwent phacoemulsification and iStent inject implantation either as a dual procedure (group A) or paired with iAccess goniotomy (group B) from July 2020 to May 2022. Effectiveness outcomes analyzed from 1month onward included intraocular pressure (IOP), proportions of eyes with IOP ≤ 12/≤ 15/≤ 18, proportion medication-free, and medication number. Safety outcomes at all timepoints included adverse events and secondary surgeries. In group A, mean IOP reduced from 14.9 ± 3.2mmHg on 1.22 ± 1.31 mean medications preoperatively (n = 63) to 13.5 ± 2.5mmHg on 0.24 ± 0.61 medications at month3 (n = 34; p = 0.048 IOP, p < 0.001 medications). In group B, mean IOP reduced from 16.0 ± 4.2mmHg on 1.12 ± 1.07 medications preoperatively (n = 93) to 12.2 ± 2.3mmHg on 0.57 ± 1.27 medications at month3 (n = 23; p < 0.001 IOP, p = 0.003 medications). From preoperative to 3months, the percent of eyes with IOP ≤ 12mmHg remained at 32.4% in group A (p = 1.0) and rose from 21.7% to 60.9% in group B (p = 0.0177); eyes with IOP ≤ 15mmHg rose from 52.9% to 76.5% in group A (p = 0.0963) and from 43.5% to 91.3% in group B (p = 0.0034). Adjusting for baseline between-group differences, group B had significantly greater postoperative IOP reduction than group A (p = 0.043); medication reductions were similar. Safety was favorable in both groups. Phacoemulsification and iStent inject with or without iAccess Precision Blade goniotomy produced clinically meaningful and safe IOP and medication reductions. The paired iStent inject + iAccess + phacoemulsification procedure enabled greater IOP reduction and lower IOP thresholds than iStent inject + phacoemulsification. The study provides some of the first data on this paired approach and on the novel iAccess Precision Blade.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.