Abstract
The aim of present study was to evaluate the effect of water flow rate on enamel surface roughness and shear bond strength (SBS) of orthodontic brackets after Er:YAG laser ablation. It is well known that external water supply is a fundamental requirement for Er:YAG laser efficiency on dental hard tissues. However, there is no consensus considering the water flow rate used during Er:YAG laser ablation. Eighty sound human upper premolar teeth were used in the present study. Seventy-six teeth were assigned into four groups according to surface treatments. The 37% phosphoric acid-etched group served as the control. Er:YAG laser irradiation was performed in three subgroups with water flow rates of 25, 36, and 48 mL/min, respectively. All specimens were subjected to a SBS test. One specimen from each different surface treatment modality was examined by scanning electron microscopy. Kruskal-Wallis test was used to compare the SBS value of each group. Although the control group had the highest SBS value, statistically no significant differences were found among groups. Er:YAG laser application with a water flow rate of 48 mL/min produced better enamel surface alterations without any thermal damage to yield higher SBS values.