Abstract
This paper presents a characteristic evaluation of piezoelectric ceramics at high vibration amplitude levels of resonance, based on the electrical transient response technique. Low-Q and high-Q materials are measured, and the effect of vibration stress is obtained without affecting temperature. It is revealed that for low-Q materials an increase of loss is caused mainly by the vibration stress, while for high-Q materials, it is caused by both the vibration stress and the temperature increase. The results show that in some high-Q materials, it is meaningless to evaluate the piezoelectric materials at low vibration level, since the characteristics change variously at high vibration levels. The force factor is changed mainly by the temperature, although its behavior is different, depending on material composition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.