Abstract
This study investigated the effects of ultrasound (US) at different frequencies on fracture healing over a three-week period in a rabbit fibular fracture model. Forty-five adult New Zealand White rabbits were divided into five groups: a control group and four groups treated with US frequencies of 0.5, 1.0, 1.5 and 2.0 MHz (0.5 W/cm 2, 200-μs burst, pulsed 1:4). After anesthesia, transverse osteotomy was performed on the fibula bone. This was followed by intravital staining and fluorescence microscopic examination of new bone formation and biomechanical tests of torsional stiffness at the osteotomy site. Results showed that total new bone formation and torsional stiffness of the fibula were greater in all US-treated groups than in the control group. No significant difference was found between any of the four US-treated groups. The US treatment also enhanced bone growth of the sham-treated contralateral fracture site. These results suggest that US treatment at 0.5, 1.0, 1.5 or 2.0 MHz can enhance fracture healing in a rabbit model. Furthermore, the effects of US on fracture healing at present parameters might not be confined locally.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.