Abstract

Most hydrodynamic fluidized bed models, including CFD codes, neglect any effects of the plenum chamber volume. Experiments were performed in a 0.13 m ID fluidization column to determine plenum chamber volume effects on fluidized bed hydrodynamics for FCC and glass particles. Two low-pressure-drop distributors were used, one with a single orifice, and the other with 33 orifices and the same total open area as the single orifice. The results show two peaks in the frequency spectra for the single-orifice distributor, one representing bubble eruption at the bed surface and the other of higher frequency corresponding to the bubbling frequency at the distributor. The latter decreased slightly with increasing plenum volume and with increasing bed depth. For the multi-orifice distributor, broad frequency spectra from pressure measurements became narrower and moved towards higher frequency with decreasing plenum volume.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.