Abstract

The main function of the vent valve is to release part of the air at the outlet of the axial compressor to prevent engine surges. The damping parameters have an important effect on the opening and closing characteristics of the vent valve. The control characteristics of each component were obtained by finite element analysis and testing. The overall model of a two-stage partial pressure vent valve was established, and the reliability of the model was verified by testing. The opening and closing characteristics of the damper valve with different damping parameters were obtained by parametric simulation. The results show that there was a pressure mutation point in the middle support pressure and the pressure in the control chamber during operation of the vent valve, which made the valve open and close quickly. The damping hole of the middle shell and the middle nozzle of the support had the greatest influence on the open-close pressure ratio. The damping hole and nozzle of the middle shell had the greatest influence on the opening and closing stability. The results are used to guide the structural design, and the analytical method provides a theoretical basis for research of the same type of valve.