Abstract

To investigate whether the response to sustained inflation and postinflation positive end-expiratory pressure varies between acute respiratory distress syndrome with pulmonary (ARDS(exp)) and extrapulmonary origin (ARDS(exp)). Prospective clinical study. Multidisciplinary intensive care unit in a university hospital. A total of 11 patients with ARDS and 13 patients with ARDS. A 7 ml/kg tidal volume, 12-15 breaths/min respiratory rate, and an inspiratory/expiratory ratio of 1:2 was used during baseline ventilation. Positive end-expiratory pressure levels were set according to the decision of the primary physician. Sustained inflation was performed by 45 cm H2O continuous positive airway pressure for 30 secs. Postinflation positive end-expiratory pressure was titrated decrementally, starting from a level of 20 cm H2O to keep the peripheral oxygen saturation between 92% and 95%. Fio2 was decreased, and baseline tidal volume, respiratory rate, inspiratory/expiratory ratio were maintained unchanged throughout the study period. Blood gas, airway pressure, and hemodynamic measurements were performed at the following time points: at baseline and at 15 mins, 1 hr, 4 hrs, and 6 hrs after sustained inflation. After sustained inflation, the Pao2/Fio2 ratio improved in all of the patients both in ARDS(p) and ARDS(exp). However, the Pao2/Fio2 ratio increased to >200 in four ARDS(p) patients (36%) and in seven ARDS(p) patients (54%). In two of those ARDS patients, the Pao2/Fio2 ratio was found to be <200, whereas none of the ARDS(p) patients revealed Pao2/Fio2 ratios of <200 at the 6-hr measurement. Postinflation positive end-expiratory pressure levels were set at 16.7 +/- 2.3 cm H O in ARDS(p) and 15.6 +/- 2.5 cm H2O in ARDS. The change in Pao /Fio ratios was found statistically significant in patients with ARDS(p) (p =.0001) and with ARDS(p) (p =.008). Respiratory system compliance increased in ARDS patients (p =.02), whereas the change in ARDS was not statistically significant. Sustained inflation followed by high levels of postinflation positive end-expiratory pressure provided an increase in respiratory system compliance in ARDS; however, arterial oxygenation improved in both ARDS forms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.