Abstract

Many problems in ion-enhanced etching are caused by the charge-up effect as the aspect ratio increases with the decrease of a semiconductor device size. The energy and angle distribution of particles are important factors in the etching process which can be controlled by the pressure of a plasma chamber. In the present paper, we varied the pressure of plasma and studied the charge-up phenomenon for the aspect ratios 5 and 10. In the low pressure RF-capacitively coupled plasma (CCP) chamber, ions with higher energy and small angle distribution have been detected. On the other hand, in the high-pressure RF-CCP chamber, ions with low-energy and high-angle distribution are observed. At a high-aspect ratio, the charge-up potential is reduced when the pressure of a plasma chamber is high. At a high pressure, more vertical etching feature is expected.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.