Abstract

In recent years, the experimental and numerical investigations of water ultraviolet (UV) reactors have increased significantly. In this study, a CFD model utilizing a Lagrangian-Eulerian method is applied to analyze the disinfection performance of a closed conduit reactor containing four low-pressure (LP) UV lamps perpendicular to the flow. A discrete ordinates (DO) model is employed to evaluate the UV irradiance field. In addition to the reference model, some other models were also defined with different number and arrangement of active lamps to examine the degree of importance of each lamp in inactivating microorganisms. The results from two inactivation kinetics show that inactivation performance of the model with two central lamps in operation corresponds to 88–99% of the reference model data. Furthermore, as a lamp is closer to the main flow region, it has more influence on microbial inactivation. The effect of water flow rate, inlet water temperature and lamp power are also studied.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.