Abstract
The effects of load level on the ability to diagnose broken bar faults in squirrel-cage induction motors are studied in this paper. The pendulous oscillation of the rotor magnetic field orientation is implemented as a fault signature for rotor fault diagnostic purposes at steady-state operations. Moreover, the effects of load level on the low-side band component of the stator current spectrum, and associated diagnostic difficulties in this approach particularly in the presence of motor operation from pulsewidth-modulation drives, are reported as well. These investigations were performed through testing 2-hp and 5-hp induction motors over a wide range of load levels and control drives. The results of these tests and investigations demonstrate the efficacy of the pendulous oscillation signature as a diagnostic means that can be used for a wide range of motor operating conditions.
Submitted Version (
Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have