Abstract

In this study, we measured the pollutants generations during cigarette smoking under various inhalation frequency experiment scenarios by a self-developed smoking machine. Some concepts, the effective inhaled amount and exposure amount were proposed to quantitatively estimate emission rates. Important findings include: For interval 1 s, 2 s, 3 s, 4 s and 9 s (called from 1 s to 9 s herein), effective inhaled nano-scale PN (particle number) per cigarette was 8.43E+09 #, 7.24E+09 #, 5.74E+ 09 #, 3.82E+09 # and 1.15E+09 #, it decreased linearly with interval time; exposure amount of PN in side stream smoke was 1.06E+10 #, 1.2E+10 #, 1.48E+10 #, 1.84E+10 # and 8.74E+10 #, it increased with interval time. For toxic gases, all pollutants decreased with interval time in main stream smoke. In side stream smoke, NOx and CO firstly increased with interval time and then decreased (with the highest value at 3 s interval time), while HC always increased with interval time. So, this study is useful to understand the relationship between pollution and smoking habit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.