Abstract

The present study investigated the effects of half-time (HT) break cooling using a fan and damp sponge on physiological and perceptual responses during the 2 nd half of a repeated-sprint exercise in a hot environment. Eight physically active men performed a familiarization trial and two experimental trials of a 2×30-min intermittent cycling exercise protocol with a 15-min HT break in hot conditions (35°C, 50% relative humidity). Two experimental trials were conducted in random order: skin wetting with a fan (FAN wet ) and no cooling (CON). During the 2 nd half, a repeated-sprint cycling exercise was performed: i. e., 5 s of maximal pedaling (body weight×0.075 kp) every minute, separated by 25 s of unloaded pedaling (80 rpm) and 30 s of rest. Rectal temperature, skin temperature (chest, forearm, thigh, and calf), heart rate, physiological strain index, rating of perceived exertion, thermal sensation, and comfort were significantly improved in the FAN wet condition (P<0.05). There was no significant difference in the repeated-sprint cycling exercise performance between conditions. The results suggest that skin wetting with a fan during the HT break is a practical and effective cooling strategy for mitigating physiological and perceptual strain during the 2 nd half in hot conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call