Abstract

When measuring blood hormones, pre-analytical sample handling can impact the quality of the results. Previous studies have shown improved stability of canine cortisol in ethylenediaminetetraacetic acid (EDTA) plasma compared to serum and interchangeability of serum and plasma when cortisol is measured by radioimmunoassay. Additionally, cortisol samples were also interchangeable when measured by chemiluminescent immunoassay if the EDTA concentration was consistent with that of optimally filled tubes, whereas excess EDTA interfered with the measurement of cortisol and serum and EDTA plasma were not interchangeable when measuring total thyroxine (TT4). The main limitation of these studies was that they were performed by spiking pooled serum samples with EDTA or in previously collected blood samples submitted to a clinical pathology laboratory. The purpose of the present study was to evaluate the effect of EDTA on the measurement of adrenocorticotropic hormone (ACTH), cortisol, TT4, free thyroxine (FT4), and thyroid stimulating hormone (TSH) in healthy dogs using the Siemens IMMULITE 1000. Whole blood from forty dogs was aliquoted into three Monoject sample tubes: no additive, completely filled EDTA tube, and 50% filled EDTA tube. Handling and storage conditions were identical, and all samples were analyzed on the same day. Bland-Altman plots and Passing-Bablok regression were used to assess agreement and risks for error, respectively. Proportional errors were found between serum and plasma samples for ACTH, cortisol, TT4, FT4, and TSH; systematic errors were also found for FT4. There was poor agreement and clinically significant differences between the measured concentrations of all hormones in serum and plasma, proving that these sample types are not interchangeable. Incompletely filled EDTA tubes were associated with significantly lower ACTH concentrations compared to completely filled EDTA tubes. When measured by chemiluminescent immunoassays that utilize alkaline phosphatase at the reporter enzyme, serum should be used for cortisol, TT4, FT4, and TSH, while plasma from completely filled EDTA tubes should be used for ACTH.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call