Abstract

The influence of composite fissure sealants on caries detection with IR laser fluorescence measurements should be assessed. Thirty-five extracted human teeth with 105 initial carious lesions were included. Six groups containing 15 lesions each were sealed with either a clear or a white version of three sealants. Group 7 was sealed with an experimental nanofilled material. Occlusal surfaces were irradiated by a diode laser (<1 mW, 655 nm). Fluorescence was measured before and after acid etching, directly and 1 week after application of the sealants. Values significantly increased after etching (p < 0.05). Compared to initial measurements, values decreased after sealing with the white materials (p < 0.05). There was no difference between values before and after sealing with the clear and the experimental materials (p > 0.05). All values were reproducible. The study indicates that it might be possible to monitor caries activity under clear or nanofilled fissure sealants by means of laser fluorescence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.