Abstract

Global mass transfer measurements in unbaffled and baffled configurations using different baffle lengths and Reynolds numbers have been made in a parallel plate cell of rectangular geometry. The entry jet arrangement and the repeated 180° changes in direction of the flow, followed by the exit, produces extremely complex hydrodynamics in the cell. A plot of mass transfer coefficient against baffle length shows an increase in mass transfer with baffle length. Comparison of data for the present work with those of other workers for similar devices showed higher mass transfer due to the modifications incorporated in the present cell.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.