Abstract

AC interference is a cause of reinforcement corrosion. Since few data are available, the influence of AC on the localized corrosion on passive carbon steel in concrete is discussed based on tests performed in alkaline solution and in concrete slabs. AC was applied in the range 10–500A/m2. Results allow stating that AC interference weakens steel passivity, increasing the passive current density, reducing both the passive interval and the [Cl−]/[OH−] molar ratio. Results confirmed that the critical alternate current density is in the range 30–100A/m2, depending on the level of chlorides present into concrete.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.