Abstract

The Supercontainer (SC) design is the preferred option for the final disposal of high level nuclear waste and spent fuel in Belgium. The SC consists of a carbon steel overpack surrounded by a very thick concrete buffer, contained within a stainless steel envelope. In this highly alkaline environment of the annulus and under normal conditions (without the ingress of aggressive species), the carbon steel overpack will be protected by a passive oxide film, which is believed to result in very low and almost negligible uniform corrosion rates. This paper discusses the modeling efforts simulating the evolution of various parameters that can potentially influence the corrosion processes (temperature, pH, saturation degree and concentration of aggressive species). The outcome of the Belgian experimental program to study the passive uniform corrosion of carbon steel in concrete is also addressed. Long-term uniform corrosion rates are determined using different independent techniques (hydrogen gas measurements by means of manometric gas cells or pressure transducers, long-term passive current density measurements).