Abstract
Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2) producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2). Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode barrier height and the efficiency of the detector as checked by alpha spectrometry. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse) current and decrease the forward current related to a deactivation of the dopant in the active detector region.
Highlights
Silicon Carbide (SiC) detectors are now-days widely employed for the monitoring of ionizing radiations
The plasma generated by high intensity laser (1016 W/cm2) producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2)
They are extensively used as diagnostic devices in laser generated plasma for both high and low intensity laser. In this field they found large application thanks to the blindness to visible light emitted from pulsed laser and to the visible component of the plasma itself. They are used in Time of Flight (TOF) configuration as this technique allows the simultaneous detection of photons, electrons and ions emitted from laser plasma; the energy of radiation can be measured with high accuracy and the detector show a
Summary
Silicon Carbide (SiC) detectors are now-days widely employed for the monitoring of ionizing radiations. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse) current and decrease the forward current related to a deactivation of the dopant in the active detector region.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have