Abstract
Collisions often happen between adjacent buildings without a sufficient gap under seismic loadings. Installing polymer bumpers may decrease the pounding forces between colliding buildings. This paper focuses on the analysis of suppressing pounding effects by using of polymer bumpers. In order to investigate pounding mitigation effectiveness in the condition with and without bumpers, different types of pounding force models are utilized to simulate and calculate frame vibration responses under seismic loads. Firstly, time-history results for pounding force, displacements, and shearing forces in selected floors are calculated in the condition with and without polymer bumpers. Secondly, differences between viscoelastic and elastic pounding force models are compared and discussed. And finally, parametric studies are carried out to investigate influences of different pounding parameters. The results show that polymer bumpers can reduce maximum values of pounding force but increase pounding times. And viscoelasticity of bumper materials has a certain range of influences on pounding force responses. Choosing improper material types and pounding parameters may lead to opposite effects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.