Abstract

Monitoring free muscle flaps with skin grafts is difficult. To intensify the monitoring process for this type of flap, a small skin paddle was included in the flap and analyzed its effects. A retrospective analysis of all patients who underwent scalp reconstruction with a free latissimus dorsi flap and skin graft between 1994 and 2016 was conducted. Flap monitoring was proceeded using a combination of clinical examination and handheld Doppler for both types of flaps. A total of 71 patients were included in this study and were divided into a study group (skin paddle included; n = 30) and a control group (conventional method; n = 41). The time between initial surgery to pedicle exploration was significantly shorter in the study group (11.3 ± 2.5 vs 79.8 ± 42.6 hours; P = .024). The flap salvage rate was significantly higher in the study group (100% vs 16.7%; P = .048). The efficacy of flap monitoring and flap salvage outcomes were improved by including a small monitoring skin flap.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.