Abstract

Gas–liquid density ratio (DR) is a key dimensionless number in sloshing assessment methodologies of membrane containment systems for LNG tanks of floating structures. Earlier studies on the effect of DR were mainly statistical and effects of DR were usually mixed with those of gas compressibility and ullage gas pressure but attributed only to DR. In an attempt to separately study such effects, part I of this work studied the effects of DR far from impact zones (global effects of gas–liquid density ratio) which proved to be small in the studied range of DR (0.0002 to 0.0060). The effects of DR near impact zones and in the instants prior to the detection of any compressibility effects are referred to as local effects and are treated in the current paper (part II).The test setup was identical to the one presented in Part I and consisted of two 2D model tanks representing transverse slices of tank 2 (out of 4) of a membrane LNG carrier with total capacity of 152000m3 at scales 1:20 and 1:40. Both model tests were performed at 20% fill level of the tank heights. Water was the main liquid that was used. In some tests at scale 1:20 a solution of sodium polytungstate (SPT) was also used which had a higher density compared to water. Different ullage gases of helium (He), air, two mixtures of sulfur hexafluoride (SF6) and nitrogen (N2), and pure SF6, all at atmospheric pressure with a range of DRs from 0.0002 to 0.0060 were utilized. Synchronized high-speed video cameras (@4000 fps) and arrays of piezo-electric PCB (112A21 and 112M361) pressure sensors (@40 kHz) monitored and measured impacts on the tank walls. In Part II of the study short and more regular tank motions which generated highly repeatable single impact waves (SIW) were used instead of long irregular tank motions which were considered in part I.By comparing the single impact waves (SIW) generated by identical tank motions but with different DRs, it was observed that DR clearly modifies wave shapes prior to the moment of wave breaking. Larger DRs tend to slow down the wave front and delay breaking. It was also observed that larger DRs slightly slow down wave trough runup as well. Those effects would also lead to a mild shift of impact types by changing the DR (for example Flip-through to slosh or large gas-pocket to small gas-pocket impacts). By comparing single impact waves (SIW) generated by identical tank motions and the same DR but with different gas and liquid densities it was shown that keeping the same DR is essentially needed to keep the same impact geometry as recommended by the existing sloshing assessment methodologies. Free surface instabilities were also very similar for those waves generated with the same tank motions and similar DR but with different gases and liquids. Considering the reduction of wave kinetic energy by heavier11Throughout the paper the term heavy gas would refer to gases with higher density and the term light gas would refer to gases with lower density. This was thought to make the text easier to read (and write) compared to the terms dense and less dense although dense and less dense are more scientific. Nonetheless wherever needed, the value of DR is mentioned explicitly. ullage gases as a relevant source of the statistical reduction of impact pressures and having in mind the mild shift of wave impact types caused by the change of DR it is still to be studied further why the heavier gas leads to smaller statistical pressures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.