Abstract

Natural Organic Matter (NOM) content in peat water is a major problem of membrane fouling in ultrafiltration (UF). For that, two stages adsorption as pre-treatment was employed to minimize the membrane fouling of NOM content. This research was carried out to investigate the effect of two stages adsorption on ultrafiltration performance for NOM removal that remains in peat water. This method was using powdered activated carbon (PAC) dosage of 80, 160, 240, 320, 400, 480, 560, 640, 720, 800, 880 dan 960 mg.L-1. Then, Polysulfone (Psf) material was employed for Ultra filtration process. Membrane was applied in a dead-end mode with various operating pressure (1; 1.5; 2; 2.5; 3 bar). As a results, the optimum dose of PAC was 800 mg L-1 with dosage ratio of 3/4:1/4. Two stages adsorption-UF PSf provided the range from 86.9 to 92.8% of KMnO4 and 74.1-88.1% of UV254. For the experimental condition of 3 bar, the highest flux was achieved up to 39.919 L h-1.m-2.