Abstract

ObjectivesThis study: 1) measures the effect of sample thickness and high irradiance on the depth-dependent time delay before photopolymerization reaction onset; 2) determines if exposure reciprocity exists; 3) measures the conversion rate at four irradiance levels; 4) determines the time, t0, at which the maximum DC rate is reached for two bulk-fill and one conventional posterior resin-based composites (RBCs). MethodsTetric PowerFill IVA shade (Ivoclar Vivadent) and Aura bulk-fill ultra universal restorative (SDI), and one conventional posterior resin-based composite (RBC), Heliomolar A3 (Ivoclar Vivadent), that were either 0.2 mm, 2 mm, or 4 mm thick were photocured using a modified Bluephase G4 (Ivoclar Vivadent) light-curing unit (LCU) that delivered a single emission band (wavelength centered at 449 nm). The same radiant exposure of 24 J/cm2 was delivered at irradiances ranging from 0.5 to 3 W/cm2 by adjusting the exposure time. PowerFill was also photocured for 3 s or 6 s using a Bluephase PowerCure LCU (Ivoclar Vivadent) on the 3 s mode setting. The degree of conversion (DC) was measured in real-time at a high temporal resolution at 30 °C using Attenuated Total Reflection (ATR) FTIR spectroscopy with a sampling rate of 13 DC data points per second. The DC data were analyzed using a phenomenological autocatalytic model. The RBC viscosity was measured at 21 °C and 30 °C. Light transmission through the RBC samples at 22 °C was monitored with time to calculate the extinction coefficients of the RBCs. ResultsThe time delay before photopolymerization started increased as the RBC thickness increased and the irradiance decreased. An autocatalytic model described the DC data. The time t0 was less than 77 ms for the 0.2 mm thick samples of PowerFill irradiated using the highest irradiance of 3 W/cm2. Among the three RBCs for each sample thickness and irradiance level, the PowerFill had the smallest time t0. There was a time delay of 0.59 s and 1.25 s before the DC started to increase at the bottom of 4 mm thick samples for the PowerFill and Aura, respectively, when an irradiance of 1 W/cm2 was delivered. The time delay increased to 3.65 s for the Aura when an irradiance of 0.5 W/cm2 was delivered.The extinction coefficients near 449 nm were 0.78 mm−1, 0.76 mm−1, and 1.55 mm−1 during the first 2 s after the start of photocuring of PowerFill, Aura, and Heliomolar, respectively. Only PowerFill followed exposure reciprocity. At T = 30 °C, the viscosity was 3400, 17000, and 5200 Paˑs for PowerFill, Aura, and Heliomolar, respectively. SignificanceThe time delay between when photopolymerization starts at the top and bottom of 2- or 4-mm thick RBC restorations may affect the structural integrity of the bond between the tooth and the bottom of the restoration. Only PowerFill followed exposure reciprocity between irradiance levels of 0.5 to 3 W/cm2. Exposure reciprocity did not occur for Aura or Heliomolar, neither of which are optimized for short light exposure or high irradiance conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call