Abstract

This study evaluated the effect of thermocycling on the tensile strength and tear resistance of four long-term soft denture liners. One light-activated (Astron Light, AL), two chemically activated (GC Reline Soft, GC; Silagum Comfort, SC), and one heat-cured (Molloplast-B, MLP) soft liner materials were tested. Dumbbell and trouser-leg specimen geometries were used for tensile strength and tear resistance tests, respectively. A total of 120 specimens were prepared. Test specimens for each material (n=5) were subjected to thermal cycling for 1000 and 3000 cycles between 5 degrees C and 55 degrees C in a thermocycler. Before thermocycling, AL gave the lowest tensile strength, while SC exhibited the highest tear resistance value among the materials tested (p < 0.05). Thermal cycling significantly affected the tensile strength of AL as well as the tear resistance values of AL, MLP, and GC materials. This in vitro study revealed that the tensile strength and tear resistance values of the soft liner materials tested varied according to their chemical compositions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.