Abstract

The article presents the results of tests related to failure analysis and finding ways to diagnose used semiconductor elements, among others, in power electronics converter systems on vessels and offshore facilities (drilling and production rigs and wind turbines). Diagnostic relationships were found between the temperature change in the above systems and the signals generated in the form of elastic waves of acoustic emission. The authors confirmed the influence of the transistor’s working temperature on its amplitude-frequency spectrum of acoustic emission signals emitted. The range of ‘safe temperatures’ was considered which means temperatures that do not directly affect the damage of the component.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.