During LOCA with ECCS failure, the removal of decay heat from the channel to a moderator plays a significant role in determining the fuel bundle temperatures. An experimental investigation has been carried out to study the effect of change in moderator temperature (65 ℃, 75 ℃, and 85 ℃) on the fuel channel at a steady state of 900 ℃ center pin temperature. The results show that at different moderator temperatures, there is insignificant variation in the temperature of PT, whereas for CT appreciable temperature gradient has been observed. The maximum heat transfer coefficient for CT was attained at 65 ℃ moderator temperature. Even with an increase in moderator temperature, channel integrity is maintained, and the moderator acts as an ultimate heat sink for all three moderator temperatures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.