Abstract

This paper addresses wave forces applied to vertical caisson breakwaters. Design diagrams are proposed to evaluate the reduction of the wave force induced by breaking and non-breaking short-crested oblique waves with increasing horizontal length of the caisson units. Results are derived by testing a model of a typical Italian vertical breakwater with a moderately high rubble mound in the CRF-LSF (Wallingford, UK) wave basin equipped with a multidirectional wave generator. Seven adjacent caisson modules were instrumented with synchronized force transducers. Non-breaking and breaking wave loads are distinguished on the basis of the frequency content. The reduction factor of the load per unit span is derived by the measured spatial correlation, following the argument developed by G. I. Taylor for random movements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.