Abstract
To assess the effect of various right ventricular pacing sites on QRS duration, we enrolled 50 patients (mean age, 64 ± 13 years; 36 men); 16 had bradycardia and 34 had tachycardia. The right ventricle was arbitrarily divided into 5 sections: high and low right ventricular outflow tract, mid septum, low septum, and apex. Right ventricular pacing was performed using an electrode catheter at each of the 5 sites. QRS duration was 162 ± 20 ms during high right ventricular outflow tract pacing, 143 ± 17 ms during low right ventricular outflow tract pacing, 151 ± 20 ms during mid-septal pacing, 163 ± 16 ms during low-septal pacing, and 167 ± 18 ms during apical pacing. Paced QRS duration was shorter during low right ventricular outflow tract and mid-septal pacing compared to apical pacing in 34 patients. There was a difference of 10 ms or less in the paced QRS duration between these pacing sites in the other 16 patients. QRS duration was shortest when the septum was paced in the right ventricle. However, QRS duration was similar during pacing in the septum and the apex in 32% of patients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.