Abstract
We report on the effect of retrace error during measurement of freeform optics using a commercial coherence scanning interferometer (CSI), and its in-built stitching capabilities. It is shown that measuring segments of freeform optics under non-null conditions, results in artifacts on the measured zone, similar to the Seidel aberrations. An experimental approach is used to quantify the induced aberrations based on the local slopes of the surface. Simulation of surfaces containing different order aberrations is shown to have a significant effect on the measurement data. A correction method is proposed that uses experimental measurements to determine the required correction based on local slope and position in the aperture. These corrections reduce the measurement difference from a comparison measurement using a Fizeau interferometer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.