Abstract
We investigated resist profile change caused by re-sticking acid from exposed area during PEB. Using high activation energy type chemically amplified positive resist, the profile changed from T-top to rounded profile with increasing Exposed Area Ratio (EAR). We thought that this profile change was caused by acid evaporation from exposed area and its re-sticking on patterned area. To estimate the effect of re-sticking acid, we performed resist sandwich tests and observed resist profile change caused by re-sticking acid. The results thereby obtained support the model we propose.To reduce the effect of re-sticking acid, we tried to use an OverCoat Layer (OCL). The effect of OCL was certified to be useful during PEB not during exposure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.