Abstract

We investigated resist profile change caused by re-sticking acid from exposed area during PEB. Using high activation energy type chemically amplified positive resist, the profile changed from T-top to rounded profile with increasing Exposed Area Ratio (EAR). We thought that this profile change was caused by acid evaporation from exposed area and its re-sticking on patterned area. To estimate the effect of re-sticking acid, we performed resist sandwich tests and observed resist profile change caused by re-sticking acid. The results thereby obtained support the model we propose.To reduce the effect of re-sticking acid, we tried to use an OverCoat Layer (OCL). The effect of OCL was certified to be useful during PEB not during exposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.