Abstract

In terms of fatigue life recovery, the beneficial effect of removing a surface layer from critical locations of components subject to high frequency elastic loading is well documented. Not so well known are the consequences of surface layer removal from parts previously subject to elasto-plastic low cycle fatigue (LCF) loading. The paper describes the results of a research project conducted to evaluate the effects of surface layer removal on subsequent LCF properties using uniaxial testpieces which have been prior cyclic deformed to different life fractions. Strain-controlled LCF tests performed on a 1%CrMoV steel at 565 °C with different strain amplitudes indicate that, following: (i) prior cyclic deformation (PCD) to nominal LCF life fractions of 0.5 and 0.8, (ii) subsequent surface damage layer removal, and (iii) test resumption; the consequent overall LCF endurances are at least as long as those accumulated without intermediate surface damage removal, and in some cases are significantly extended. Unlike the possibilities associated with elastic fatigue loading, LCF lifetimes are not fully recoverable following the removal of prior cyclic surface damage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.